Light curtains, a vital safety measure in industrial automation, machine safeguarding, and access control, rely on robust safety circuit design for reliable operation. This circuit design ensures safety by detecting obstructions, eliminating hazardous situations, and preventing accidents. Understanding and correctly implementing light curtain safety circuits is paramount for any safety engineer or designer.

The primary function of a light curtain safety circuit is to emit and receive a beam of light from one side to another. If an object obstructs this beam, the receiving photocells do not receive the light signal, triggering an action like stopping a machine or emitting an alarm.

Light Curtain Components

A typical light curtain consists of two primary components: the emitter and the receiver. The emitter comprises a string of light sources, usually infrared LEDs, while the receiver has a corresponding array of light-sensitive detectors or photocells.

AD
8 Beams Safety Infared Light Curtain Sensors 20mm Pitch 8 Optical Axis Industrial Laser Beam Light
8 Beams Safety Infared Light Curtain Sensors 20mm Pitch 8 Optical Axis Industrial Laser Beam Light
BEM0820‑C‑140NB Capteur d'écran de rideau lumineux de sécurité 20 mm Réseau infrarouge
BEM0820‑C‑140NB Capteur d'écran de rideau lumineux de sécurité 20 mm Réseau infrarouge
the instructions for how to install an electric fence with wood posts and handrails
the instructions for how to install an electric fence with wood posts and handrails

Connecting these components together is the safety circuit, which can be categorized into two types: discreet channel and diffuse mode. In discreet channel, each LED-photocell pair forms a discrete channel, while in diffuse mode, several LEDs and photocells can share two or more channels for cost-effectiveness.

Safety Categories and Standards

Light curtain safety circuits fall under different safety categories based on the risk reduction they provide. The most common categories are CAT2 and CAT3. CAT2 provides Stop 1 functionality, ensuring that a machine stops within a specified time after the hazardous movement has stopped. CAT3, on the other hand, provides Stop 1 and Stop 2 functionalities, adding muting rejection for deliberate bypassing.

Automatic Curtain Open-Close Circuit
Automatic Curtain Open-Close Circuit
Introduction to Safety Light Curtains: Operation and Installation - Technical Articles
Introduction to Safety Light Curtains: Operation and Installation - Technical Articles
MSF4800S-20-0920-R | Omron MSF4800 Safety Light Curtain
MSF4800S-20-0920-R | Omron MSF4800 Safety Light Curtain

These circuits also adhere to international safety standards, such as EN ISO 13855 for safety of machinery, and EN 61496 for functional safety. These standards outline the design, operation, and performance requirements for light curtains.

Environmental Factors and Immunity

A well-designed safety circuit should account for various environmental factors. Factors like electromagnetic interference, temperature extremes, and mechanical shock can affect the performance of light curtains. Therefore, the circuit design should incorporate measures like electromagnetic compatibility, thermal management, and robust mechanical design to ensure reliable operation under harsh conditions.

AD

Immunity testing is crucial in ensuring the light curtain's performance in real-world conditions. This includes tests for EMC immunity, electrostatic discharge, power supply, hygienic cleanability, and more, depending on the application and environment.

Banner Expands Safety Light Curtains To Include More Lengths - News
Banner Expands Safety Light Curtains To Include More Lengths - News
Safety Light Curtain 10m with Alarm for Industrial Use
Safety Light Curtain 10m with Alarm for Industrial Use
How to Choose Safety Light Curtain? Garantta Full Series Industrial Safety Barrier
How to Choose Safety Light Curtain? Garantta Full Series Industrial Safety Barrier
an image of a curtain with light coming through it in the middle of a room
an image of a curtain with light coming through it in the middle of a room
Infrared Safety Light Curtain 60m Alarm Sensor
Infrared Safety Light Curtain 60m Alarm Sensor
New Products From Banner Engineering: Light Curtain and Edge Sensor - News
New Products From Banner Engineering: Light Curtain and Edge Sensor - News

Designing a Light Curtain Safety Circuit

Designing a safety circuit involves several steps, starting with a risk assessment to identify potential hazards. Based on this assessment, the appropriate type of light curtain and safety circuit can be selected. Regular maintenance and testing are also crucial to ensure the circuit's performance over time.

Safety relays, which are output devices that initiate the safety function upon detecting an interruption in the light curtain's beam, are an essential part of the design. They must be appropriately rated for the specific application, with factors like the number of outputs, switching capacity, and response time considered.

AD

Light Curtains and Machines

When designing light curtain safety circuits for machines, it's crucial to consider the machine's cycle of operation. This may involve muting, where the light curtain permits machine operation during specific cycles, or phi-amplitude safety, which uses a graduated field to protect against inching movements.

a room with wooden floors and a large curtain hanging from the ceiling in front of it
a room with wooden floors and a large curtain hanging from the ceiling in front of it
an image of the corner of a window with blinds on it's side and light coming from behind
an image of the corner of a window with blinds on it's side and light coming from behind
many wires are connected to the back of a large metal structure with red and yellow lights
many wires are connected to the back of a large metal structure with red and yellow lights
전선
전선
a large room with lights hanging from the ceiling
a large room with lights hanging from the ceiling
a comic strip showing how to use the light source for an image with caption that reads, factory surveillance lights visibility & prevent
a comic strip showing how to use the light source for an image with caption that reads, factory surveillance lights visibility & prevent
Traffic Light Circuit with 555 IC #Shorts
Traffic Light Circuit with 555 IC #Shorts
Instagram Reception Curtain, Massage Center, Metal Curtain, Spa Massage, Curtain Lights, Curtains, Lighting, Hotel, Wall
Instagram Reception Curtain, Massage Center, Metal Curtain, Spa Massage, Curtain Lights, Curtains, Lighting, Hotel, Wall
light curtain safety circuit design
light curtain safety circuit design
Curtain Opener Circuit
Curtain Opener Circuit
an empty room with many circular lights on the ceiling and floor, all lit up in red
an empty room with many circular lights on the ceiling and floor, all lit up in red
an electronic device is connected to a light bulb
an electronic device is connected to a light bulb
an orange curtain hanging from the ceiling in a room with red walls and flooring
an orange curtain hanging from the ceiling in a room with red walls and flooring

Additionally, the design should account for fine adjustment ranges to accommodate variations in machine size and operation. Proper alignment and mounting of light curtains are also critical for optimal performance.

Safety Controllers and Logic

Safety controllers, integrated circuits designed specifically for safety functions, can be used to create complex safety logic. They can handle multiple light curtains, safety gates, and other safeguards, ensuring machine safety and high availability.

AD

These controllers allow for the implementation of advanced safety functions, like safe direction monitoring, which ensures that the machine only operates in safe directions, or safe speed monitoring, which keeps machine speeds below safe limits.

In the realm of industrial safety, light curtain safety circuits play a pivotal role in preventing accidents and ensuring machine guarding. As technology advances, so do the applications and capabilities of these safety circuits. Regular training, updates on standards, and innovative design approaches are key to maintaining cutting-edge safety solutions in today's rapidly evolving industrial landscape.

AD